Ideal transformer ratio
An ideal 5:1 transformer steps 120 V down to 24 V into a 10 Ω load, and the currents step up by the same ratio.
The ideal transformer enforces two relations and nothing else:
With
Both windings need a ground reference. The source's return and the bottom of each winding are grounded here; an isolated secondary with no reference would leave its node voltages undefined.
The plot shows vp and vs on the top axis and the winding currents ip and is below.
Things to try
- Change
turns_ratioto 0.5 and the transformer steps up: 240 V across the load. - Replace the source with a DC source. The ideal transformer passes it unchanged, which a real transformer, whose magnetizing inductance shorts DC, cannot do. The transformer energization sample shows the real behaviour.
The run is 50 ms at a 20 µs step.