Appearance
Six-pulse bridge commutation overlap
A three-phase diode bridge feeding a stiff 100 A DC load through 1 mH of source inductance, so each diode hand-over takes a measurable overlap angle.
With no source inductance, a six-pulse bridge hands the DC current from one diode to the next instantly and its average output is the textbook
With ia, ib and ic in the plot.
The DC side floats, so the plot shows both rail voltages to ground, vdc_p and vdc_n. The DC voltage is their difference. The load is a current source because a stiff current is the assumption the formula is built on; it ramps up over the first 20 ms, and a 10 kΩ shunt keeps the DC rails defined while it does.
A damping resistor on the source inductance
The source is set to the R-R||L impedance, with a 400 Ω resistor across each 1 mH inductor. At 60 Hz the resistor is invisible: it adds well under a milliohm of equivalent series resistance. It is there for the instant each diode turns off. The outgoing phase's inductor current is cut by an opening switch, and the trapezoidal rule answers a cut inductor current with a sign-alternating voltage that rings at the step rate. 400 Ω is
Things to try
- Set the source impedance back to plain
R-L. The averages barely move, but every commutation now ends with a burst of alternating spikes on the DC rails that peaks near 670 V, well above the 566 V line-voltage peak. - Double the load current to 200 A. The overlap widens to about 43° and the average drops by another 36 V.
- Set the source inductance to 0. The phase currents become square blocks and the DC voltage climbs to the ideal 540 V.
The run is 100 ms at a 5 µs step.