Appearance
Integrator
Continuous-time integrator: out = K * ∫ in dt + x₀. Optional output saturation for anti-windup. Common in PID controllers and physical models.
Category: Continuous
Ports
| Port | Kind | Signal | Notes |
|---|---|---|---|
in | Control input | Real | |
out | Control output | Real |
Parameters
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| K | Number | 1 | — | gain | |
| x₀ | Number | 0 | — | initial_value | |
| Saturation | Choice: Off / On | Off | — | Clamp the integrator state to [lower_limit, upper_limit]. Provides anti-windup. | saturation |
| x_max | Number | 1 | — | upper_limit | |
| x_min | Number | -1 | — | lower_limit |