Skip to content

Integrator ​

Continuous-time integrator: out = K * ∫ in dt + x₀. Optional output saturation for anti-windup. Common in PID controllers and physical models.

Category: Continuous

Ports ​

PortKindSignalNotes
inControl inputReal
outControl outputReal

Parameters ​

ParameterTypeDefaultUnitsDescriptionID
KNumber1—gain
x₀Number0—initial_value
SaturationChoice: Off / OnOff—Clamp the integrator state to [lower_limit, upper_limit]. Provides anti-windup.saturation
x_maxNumber1—upper_limit
x_minNumber-1—lower_limit

In the course ​