Breaker (3-phase) ​

Three-phase circuit breaker — three independent poles (one per phase) sharing a single open/close command. Each pole acts as a small R_on resistance when closed and a very large R_off resistance when open. The command comes from a wired control input, a named signal (0 = open, > 0 = close), or a built-in time schedule that toggles all three poles open↔closed at each time in a list (starting from a chosen initial state — no wiring needed). When commanded to open, each pole independently holds closed until its own through-current can be interrupted — its magnitude falls to the Interrupt-current threshold, or its phase current crosses zero — so the three poles generally clear at slightly different instants (realistic AC behaviour); this per-pole clearing applies to a time-triggered open as well. Set the threshold large to open instantly under load, 0 to wait for a natural AC zero. A separate Load-flow state switch decides whether the power-flow (load-flow) analysis treats the breaker as a closed low-impedance branch between its two buses or leaves it out (open); it is independent of the time-domain command and t = 0 state. Optional per-phase current and open/closed-state observables. No arc model.

Category: Three-Phase / Switching

Ports ​

PortKindSignalNotes
leftThree-phase terminal—
rightThree-phase terminal—
ctrlControl inputIntegerShown when Trigger source is Control input

Parameters ​

Config ​

ParameterTypeDefaultUnitsDescriptionID
R_onNumber0.001Ω (also kΩ, MΩ)Closed-state per-pole resistance. Pick a unit from the dropdown.resistance_on
R_offNumber1000000000Ω (also kΩ, MΩ)Open-state per-pole resistance. Pick a unit from the dropdown.resistance_off
Trigger sourceChoice: Control input / Named signal / Time triggeredControl input—Where the shared open/close command comes from. `Control input`: a wired `ctrl` port (hidden for the other sources). `Named signal`: a portless signal resolved by name (GoTo / labelled wire / another component's observable), read 1-step delayed. `Time triggered`: a built-in schedule toggles all three poles open↔closed at each time on the Trigger time(s) list, starting from the Initial state (no wiring needed). For Control input / Named signal the command is an integer signal: 0 = open, any value > 0 = close, applied to all three poles (wire a flag block such as Relational Double or Relational Int, or convert a double with Double → Int).trigger_source
Trigger signal nameText(empty)—Name of the published signal that commands all three poles when Trigger source is `Named signal` (0 = open, > 0 = close). Resolved through the shared signal names and read 1-step delayed. Blank reads 0 (breaker stays open).trigger_signal_name
Trigger time(s)Text(empty)—Comma-separated trigger times in seconds, e.g. `2` or `2,4,6`. All three poles toggle state (open↔closed) at each time, starting from the Initial state. Blank = never toggles (stays at the Initial state for the whole run). A time-triggered open still respects the Interrupt current threshold below (instant by default).trigger_times
Initial stateChoice: Open / ClosedClosed—Breaker state at t = 0 (the state before the first trigger time), and the symbol drawn on the canvas (Closed = arm bridges the contacts; Open = arm lifted). Time-triggered mode only.initial_state
Interrupt currentNumber1000000000A (also kA)Largest per-pole through-current the breaker can interrupt the instant it is commanded open. While opening, each pole stays closed until its |I| falls to this value OR its phase current crosses zero, then opens. Default is very large, so all poles open immediately under any load (an abrupt chop; the inductive L·di/dt shows up as a voltage spike). Set 0 to wait for each phase's natural current zero (ideal AC interruption); a small value models a vacuum breaker's chopping current. Note: with 0 on a DC current (no zero crossing) that pole stays closed.interrupt_current
Load-flow stateChoice: Open / ClosedClosed—Breaker state seen by the power-flow (load-flow) analysis ONLY — it does not affect the time-domain run, the EMT t = 0 state, or the open/close command above. `Closed`: the breaker appears in the load-flow case as a low-impedance branch (R = R_on, per pole) tying its two buses, so power flows through it. `Open`: the breaker is left out of the load-flow case, disconnecting the two sides. To take effect, wire `left` and `right` to two different buses — a closed breaker whose ports are not both on buses is reported as an unconnected branch and skipped.loadflow_state
Measure currentChoice: Off / OnOff—Emit per-phase branch currents (A) flowing left → right as simulator observables.measure_current
Positive directionChoice: +ve in / +ve out+ve in—Sign convention for this current. '+ve in' (default) is positive when current flows into the left terminal, toward the right, on every phase. '+ve out' flips the sign.current_dir
Measure stateChoice: Off / OnOff—Emit each pole's actual state as a simulator observable (1 = closed, 0 = open). Useful because the poles lag the command — and each other — while waiting to interrupt.measure_state

Signal Names ​

ParameterTypeDefaultUnitsDescriptionID
Phase A current nameTextIa—Signal name for Phase A branch current. Blank skips this phase.current_name_a
Phase B current nameTextIb—Signal name for Phase B branch current. Blank skips this phase.current_name_b
Phase C current nameTextIc—Signal name for Phase C branch current. Blank skips this phase.current_name_c
Phase A state nameTextBRKa—Signal name for Phase A pole state (1 = closed, 0 = open). Blank skips this phase.state_name_a
Phase B state nameTextBRKb—Signal name for Phase B pole state (1 = closed, 0 = open). Blank skips this phase.state_name_b
Phase C state nameTextBRKc—Signal name for Phase C pole state (1 = closed, 0 = open). Blank skips this phase.state_name_c

Observables ​

Default nameKindRecorded whenDescriptionID
set by Phase A current nameSignalMeasure current is onPhase A branch current, left → right (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign.branchCurrent_a
set by Phase B current nameSignalMeasure current is onPhase B branch current, left → right (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign.branchCurrent_b
set by Phase C current nameSignalMeasure current is onPhase C branch current, left → right (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign.branchCurrent_c
set by Phase A state nameSignalMeasure state is onPhase A pole state (1 = closed, 0 = open).breakerState_a
set by Phase B state nameSignalMeasure state is onPhase B pole state (1 = closed, 0 = open).breakerState_b
set by Phase C state nameSignalMeasure state is onPhase C pole state (1 = closed, 0 = open).breakerState_c