Appearance
Capacitor (3-phase)
Three-phase capacitor bank — three identical capacitors connected between the line ports and a neutral (Y) or between phases (delta). Used for power-factor correction and harmonic filtering.
Category: Three-Phase / Passive
Ports
| Port | Kind | Signal | Notes |
|---|---|---|---|
left | Three-phase terminal | — | |
right | Three-phase terminal | — |
Parameters
Config
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| C | Number | 0.01 | — | Per-phase capacitance (F). The 3-phase capacitor is three independent per-phase capacitors sharing this value, no neutral coupling. | capacitance |
| Measure current | Choice: Off / On | Off | — | Emit per-phase branch current as simulator observables. | measure_current |
| Positive direction | Choice: +ve in / +ve out | +ve in | — | Sign convention for this current. '+ve in' (default) is positive when current flows into the left terminal, toward the right, on every phase. '+ve out' flips the sign. | current_dir |
Current Monitoring
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| Phase A current name | Text | Ia | — | Signal name for Phase A branch current. Blank skips this phase. | current_name_a |
| Phase B current name | Text | Ib | — | Signal name for Phase B branch current. Blank skips this phase. | current_name_b |
| Phase C current name | Text | Ic | — | Signal name for Phase C branch current. Blank skips this phase. | current_name_c |
Observables
| Default name | Kind | Recorded when | Description | ID |
|---|---|---|---|---|
| set by Phase A current name | Signal | Measure current is on | Phase A branch current (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign. | branchCurrent_a |
| set by Phase B current name | Signal | Measure current is on | Phase B branch current (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign. | branchCurrent_b |
| set by Phase C current name | Signal | Measure current is on | Phase C branch current (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign. | branchCurrent_c |