Appearance
Transmission Line (Bergeron half)
One island-local terminal of a split Bergeron transmission line. Not placed directly — the netlist converter emits a pair of these (roles a/b) for each travelling-wave line whose one-way travel time clears the time step, so the two circuits decouple into separate electrical islands and exchange delayed history through arena rings. The lumped PI / short-line fallback uses the two-port Transmission Line component instead.
Category: Transmission
Ports
| Port | Kind | Signal | Notes |
|---|---|---|---|
end | Electrical terminal | — | Shown when Conductors is 1 |
end3 | Three-phase terminal | — | Shown when Conductors is 3 |
Parameters
| Parameter | Type | Default | Units | Description | ID |
|---|---|---|---|---|---|
| Conductors | Choice: 1 / 3 | 1 | — | 1 = single-phase (port end), 3 = three-phase (port end3). | number_of_conductors |
| R (Ω) | Number | 1 | — | Single-phase total series resistance (canonical). | R |
| L (H) | Number | 0.1 | — | Single-phase total series inductance (canonical). | L |
| C (F) | Number | 0.000001 | — | Single-phase total shunt capacitance (canonical). | C |
| R1 (Ω) | Number | 3 | — | Positive-sequence total series resistance (canonical, 3-phase). | R1 |
| L1 (H) | Number | 0.09 | — | Positive-sequence total series inductance (canonical, 3-phase). | L1 |
| C1 (F) | Number | 0.0000012 | — | Positive-sequence total shunt capacitance (canonical, 3-phase). | C1 |
| R0 (Ω) | Number | 30 | — | Zero-sequence total series resistance (canonical, 3-phase). | R0 |
| L0 (H) | Number | 0.26 | — | Zero-sequence total series inductance (canonical, 3-phase). | L0 |
| C0 (F) | Number | 8e-7 | — | Zero-sequence total shunt capacitance (canonical, 3-phase). | C0 |
Observables
| Default name | Kind | Recorded when | Description | ID |
|---|---|---|---|---|
| set by Current name | Signal | Emit 1ph current is on | Single-phase current at this terminal, scaled to the chosen unit (A / kA). Positive 'out of this end into the line' unless the terminal selects '+ve in'. | branchCurrent |
| set by Phase A current name | Signal | Emit 3ph current is on | Phase A current at this terminal, scaled to the chosen unit (A / kA). | branchCurrent_a |
| set by Phase B current name | Signal | Emit 3ph current is on | Phase B current at this terminal, scaled to the chosen unit (A / kA). | branchCurrent_b |
| set by Phase C current name | Signal | Emit 3ph current is on | Phase C current at this terminal, scaled to the chosen unit (A / kA). | branchCurrent_c |