Skip to content

Inductor (3-phase) ​

Three-phase inductor — three identical inductors per phase. Used as a series reactor or smoothing reactor in 3-phase networks.

Category: Three-Phase / Passive

Ports ​

PortKindSignalNotes
leftThree-phase terminal—
rightThree-phase terminal—

Parameters ​

Config ​

ParameterTypeDefaultUnitsDescriptionID
LNumber0.001—Per-phase inductance (H). The 3-phase inductor is three independent per-phase inductors sharing this value, no mutual coupling.inductance
Measure currentChoice: Off / OnOff—Emit per-phase branch current as simulator observables.measure_current
Positive directionChoice: +ve in / +ve out+ve in—Sign convention for this current. '+ve in' (default) is positive when current flows into the left terminal, toward the right, on every phase. '+ve out' flips the sign.current_dir

Current Monitoring ​

ParameterTypeDefaultUnitsDescriptionID
Phase A current nameTextIa—Signal name for Phase A branch current. Blank skips this phase.current_name_a
Phase B current nameTextIb—Signal name for Phase B branch current. Blank skips this phase.current_name_b
Phase C current nameTextIc—Signal name for Phase C branch current. Blank skips this phase.current_name_c

Observables ​

Default nameKindRecorded whenDescriptionID
set by Phase A current nameSignalMeasure current is onPhase A branch current (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign.branchCurrent_a
set by Phase B current nameSignalMeasure current is onPhase B branch current (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign.branchCurrent_b
set by Phase C current nameSignalMeasure current is onPhase C branch current (A). Positive into the left terminal, toward the right, on every phase for '+ve in' (default); the other direction flips the sign.branchCurrent_c