RLC Branch ​

Single-phase series-RLC branch — a two-terminal branch whose impedance is a series R + jωL + 1/(jωC), integrated in the time domain with a single trapezoidal R+L+C Norton companion. Enter each of R, L and C in its own unit, chosen from the dropdown (Ω / kΩ / pu / Siemens for R; H / mH / pu / X reactance / X.pu for L; F / µF / pu / B susceptance / B.pu for C); the pu / reactance / susceptance options read the bases from the Units tab. Set any element to 0 to remove it — the element is shorted out, drawn as a plain wire, and the icon tag shrinks to the elements that remain (e.g. RL when C = 0). Use for snubbers, damping branches, series filters, or any single-phase branch that is a series combination of R, L and (optionally) C. The three-phase sibling is the RLC Branch (3-phase).

Category: Single-Phase / Passive

Ports ​

PortKindSignalNotes
iElectrical terminal—
jElectrical terminal—

Parameters ​

Config ​

ParameterTypeDefaultUnitsDescriptionID
RNumber1Ω (also kΩ, pu, S)Series resistance. Pick a unit from the dropdown; pu / Siemens conversions read the bases from the Units tab. Drives the R part of the EMT trapezoidal companion. Enter 0 to remove the resistor (shorted out — drawn as a plain wire).r_ohms
LNumber0.001H (also mH, pu, Ω, X.pu)Series inductance. Pick a unit from the dropdown; pu / X (Ω reactance) / X.pu conversions read the bases from the Units tab. Drives the L part of the EMT trapezoidal companion. Enter 0 to remove the inductor (shorted out — drawn as a plain wire).l_henries
CNumber0F (also μF, pu, S, B.pu)Series capacitance. Pick a unit from the dropdown; pu / B (Siemens susceptance) / B.pu conversions read the bases from the Units tab. Drives the C part of the EMT trapezoidal companion. Default 0 = no capacitor (pure series-RL). Enter 0 to remove the capacitor (shorted out — drawn as a plain wire).c_farads
Measure currentChoice: Off / OnOff—Emit the series-branch current (positive = `i` → `j`) as a simulator observable. The signal name is on this row; blank skips it.measure_current
Positive directionChoice: +ve in / +ve out+ve in—Sign convention for this current. '+ve in' (default) is positive when current flows into port i, toward j. '+ve out' flips the sign.current_dir

Current Monitoring ​

ParameterTypeDefaultUnitsDescriptionID
Current nameTextI—Signal name for the measured branch current. Change the default `I` when you have multiple measured components — duplicate ids collide. Blank skips emission.current_name

Units ​

ParameterTypeDefaultUnitsDescriptionID
S_base (MVA)Number100—System base apparent power in MVA. Used by `pu` impedance / admittance conversions in this component's `computations` block.S_base
V_base (kV)Number230—Base RMS line-to-line voltage in kV. Used by `pu` impedance / admittance conversions in this component's `computations` block.V_base
Frequency (Hz)Number60—Frequency in Hz. Used by `B` (susceptance) / `X` (reactance) conversions in this component's `computations` block.Freq

Observables ​

Default nameKindRecorded whenDescriptionID
set by Current nameSignalMeasure current is onSeries-branch current (A). Positive = current flowing from `i` to `j`. The direction switch keeps this sign by default and flips it the other way.branchCurrent

Used in samples ​